Civil and concrete anodes
Anodes that protect steel reinforcement in concrete and the steel elements of bridges, ports and waterfront structures.

Reinforced concrete, bridges, ports and waterfront structures.
When chlorides from seawater or de-icing salts reach the steel inside concrete, the reinforcement corrodes, expands and cracks the concrete around it. Galvanic anodes embedded in the concrete corrode in place of the steel and slow this process — extending the life of repairs and structures.
For waterfront infrastructure, sacrificial anodes also protect steel piles, sheet piling, dock gates and intake structures where they meet seawater.
- Zinc in activating mortar (concrete anodes)
- Aluminium-zinc-indium (seawater steel structures)
- Zinc (seawater and saline mud)
All 17 civil and concrete anodes.
-
E01
Concrete Galvanic Anodes
Zinc anodes encased in an activating mortar, embedded in concrete to protect the reinforcement around them.
-
E02
Discrete Concrete Anodes
Anodes installed in drilled holes in sound concrete to protect reinforcement over a wider area.
-
E03
Embedded Zinc Anodes
Zinc anodes cast into new concrete or repair areas and connected to the reinforcement.
-
E04
Reinforced Concrete Anodes
Anodes for general protection of reinforced concrete elements exposed to chlorides.
-
E05
Concrete Patch Repair Anodes
Anodes fixed to exposed reinforcement at the edge of patch repairs, reducing new corrosion around the repair.
-
E06
Bridge Structure Anodes
Anodes for bridge piers, beams and substructures.
-
E07
Bridge Deck Anodes
Anodes for bridge decks affected by de-icing salts or marine exposure.
-
E08
Pier Structure Anodes
Anodes for concrete and steel piers in marine environments.
-
E09
Piling Protection Anodes
Anodes for steel tubular and H-piles below the waterline.
-
E10
Jetty Structure Anodes
Anodes for jetty piles, deck supports and berthing structures.
-
E11
Harbour Structure Anodes
Anodes for breakwaters, dolphins and harbour steelwork.
-
E12
Quay Wall Anodes
Anodes for steel and reinforced concrete quay walls.
-
E13
Dock Gate Anodes
Anodes for dry-dock gates, caissons and lock gates.
-
E14
Sheet Pile Anodes
Anodes for steel sheet piling in seawater and brackish water.
-
E15
Water Intake Structure Anodes
Anodes for intake screens, culverts and pump bays at power and desalination plants.
-
E16
Dam Structure Anodes
Anodes for steel gates, penstocks and submerged dam components.
-
E17
Reinforced Foundation Anodes
Anodes for reinforced concrete foundations in chloride-contaminated or aggressive ground.
No products match your search. Ask our team — we may still be able to help.
Where these anodes are used.
Bridges and highways
Decks, piers and substructures exposed to chlorides.
Ports and harbours
Jetties, quay walls, piles and sheet piling.
Buildings and car parks
Concrete repairs in chloride-contaminated structures.
Water infrastructure
Intakes, dams, gates and culverts.
What to include in your enquiry.
- Structure type and condition survey, if available
- Concrete or steel element to be protected
- Repair method and area
- Exposure (seawater, splash zone, de-icing salts)
- Required design life
- Quantities and programme
Common questions.
What does a galvanic concrete anode do?
It contains zinc that corrodes in place of the reinforcing steel. Fixed to the reinforcement in a repair or drilled hole, it slows corrosion of the surrounding steel.
Why use anodes in patch repairs?
Repairing one area can accelerate corrosion in the surrounding concrete — known as the incipient anode or halo effect. Anodes at the edge of the repair help prevent this.
Are galvanic or impressed current systems better for concrete?
Galvanic anodes are simple and need no power supply, which suits targeted repairs. Impressed current systems, using MMO mesh or ribbon anodes, are often chosen for large areas or long design lives.
Can you supply anodes for steel piles?
Yes. We supply weld-on and bolt-on anodes for steel tubular piles, H-piles and sheet piling.