Pipeline and tank anodes
Galvanic anodes for buried pipelines, storage tanks, casings and wells — where soil and fresh water demand a different approach to seawater.

Buried pipelines, storage tanks, casings and wells.
Onshore pipelines and tanks sit in soil or fresh water, where electrolyte resistivity is much higher than in seawater. Magnesium anodes, with their high driving voltage, are the usual choice — often supplied pre-packaged in a low-resistivity backfill that improves performance and stabilises current output.
We supply magnesium and zinc anodes in block, rod, ribbon and pre-packaged forms, together with anodes for tank internals, tank bottoms, casings and wells.
- Magnesium — standard and high-potential alloys
- Zinc (low-resistivity soils, ribbon and grounding)
- Aluminium (tank internals with water bottoms)
All 19 pipeline and tank anodes.
-
C01
Pre-Packaged Anodes
Magnesium or zinc anodes supplied in a cotton bag with gypsum, bentonite and sodium sulphate backfill, ready for burial.
-
C02
Bare Magnesium Anodes
Magnesium anodes without backfill, for use in water or where backfill is placed separately.
-
C03
Drive-In Magnesium Anodes
Pointed magnesium anodes that can be driven directly into soft ground, avoiding excavation.
-
C04
Extruded Magnesium Rod Anodes
Extruded magnesium rods for water heaters, condensers, tanks and small structures.
-
C05
Magnesium Ribbon Anodes
Continuous magnesium ribbon laid alongside pipelines in high-resistivity soil, in casings or for temporary protection.
-
C06
Zinc Ribbon Anodes
Continuous zinc ribbon used for pipeline protection, AC mitigation and grounding, and under tank bottoms.
-
C07
Tank Internal Anodes
Anodes installed inside tanks to protect the floor and lower shell in contact with water.
-
C08
Tank Bottom Anodes
Anodes protecting the soil side of tank bottoms, installed beneath or around the tank.
-
C09
Tank Floor Anodes
Anodes for tank floor plates, including systems installed during tank construction or floor replacement.
-
C10
Tank External Anodes
Buried anodes protecting the external surfaces of underground and partly buried tanks.
-
C11
Oil Storage Tank Anodes
Internal and external anodes for crude and product storage tanks, including water-bottom protection.
-
C12
Water Storage Tank Anodes
Anodes for potable, process and fire water tanks.
-
C13
Fuel Tank Anodes
Anodes for underground and above-ground fuel storage tanks.
-
C14
Casing Anodes
Anodes for pipeline casings at road, rail and river crossings.
-
C15
Well Casing Anodes
Anodes for oil, gas and water well casings.
-
C16
Borehole Anodes
Anodes for installation in vertical boreholes where surface space is limited or soil near the surface has high resistivity.
-
C17
Groundbed Anodes
Galvanic anode groundbeds — multiple anodes connected together to deliver the required current.
-
C18
Pipeline Test Anodes
Anodes used for current-requirement surveys, field tests and test-station installations.
-
C19
Temporary Pipeline Anodes
Anodes that protect pipelines during construction, before the permanent CP system is energised.
No products match your search. Ask our team — we may still be able to help.
Where these anodes are used.
Buried pipelines
Oil, gas and water transmission and distribution lines.
Storage tanks
Oil, fuel, water and process storage tanks.
Wells and casings
Well casings, crossings and boreholes.
AC mitigation and grounding
Zinc ribbon for induced-AC mitigation and earthing.
What to include in your enquiry.
- Structure type (pipeline, tank, casing, well)
- Soil or water resistivity, if known
- Anode type and material
- Bare or pre-packaged; anode and bag dimensions
- Cable type and length
- Quantity and delivery schedule
Common questions.
Why are magnesium anodes used for buried pipelines?
Soil typically has much higher resistivity than seawater. Magnesium has the highest driving voltage of the common anode metals, so it can deliver useful current in these conditions.
What is the backfill in a pre-packaged anode?
Typically a mixture of gypsum, bentonite and sodium sulphate. It keeps moisture around the anode, lowers contact resistance and helps the anode consume evenly.
When is zinc ribbon used?
Zinc ribbon is used in lower-resistivity soils, for AC mitigation and grounding along pipelines, and beneath tank bottoms.
Can you supply anodes with cables attached?
Yes. Anodes can be supplied with lead wires of the specified type, size and length.