Skip to content
Category F · 30 products

Impressed current anodes

Long-life anodes for impressed current cathodic protection (ICCP) systems on pipelines, tanks, marine structures and reinforced concrete.

Impressed current anodes
Overview

MMO, platinised, high-silicon iron, graphite and polymer anodes.

In an impressed current system, a transformer-rectifier drives protective current from inert or slowly consumed anodes into the soil or water and onto the steel. Because the current comes from a power supply rather than from the anode metal itself, a few anodes can protect very large structures for many years.

We supply the main ICCP anode technologies — mixed metal oxide (MMO) coated titanium, platinised titanium and niobium, high-silicon cast iron, graphite and conductive polymer — in tubular, rod, wire, ribbon, mesh, plate and canister forms, together with anodes for deep and shallow groundbeds.

Typical materials
  • Mixed metal oxide (MMO) coated titanium
  • Platinised titanium and niobium
  • High-silicon cast iron (HSCI)
  • Graphite
  • Conductive polymer
Product list

All 30 impressed current anodes.

  1. F01

    MMO Titanium Anodes

    Titanium anodes with a mixed metal oxide coating — compact, lightweight and with a very low consumption rate.

  2. F02

    MMO Tubular Anodes

    MMO-coated titanium tubes for groundbeds, deep wells, seawater and tank applications.

  3. F03

    MMO Rod Anodes

    Solid MMO-coated titanium rods for tanks, vessels and probe-type installations.

  4. F04

    MMO Wire Anodes

    Flexible MMO-coated titanium wire for linear anodes inside tanks and along pipelines.

  5. F05

    MMO Ribbon Anodes

    MMO-coated titanium ribbon, widely used for reinforced concrete and tank bottom systems.

  6. F06

    MMO Mesh Anodes

    Expanded MMO titanium mesh for protecting large concrete surfaces such as bridge decks and car parks.

  7. F07

    MMO Mesh Ribbon Anodes

    Narrow strips of MMO mesh, embedded in slots or overlays in reinforced concrete.

  8. F08

    MMO Flexible Linear Anodes

    MMO wire inside a permeable jacket packed with conductive backfill, laid alongside pipelines or under tank bottoms.

  9. F09

    MMO Strip Anodes

    Flat MMO-coated titanium strip for concrete and specialised installations.

  10. F10

    MMO Plate Anodes

    MMO-coated titanium plates for seawater structures, intakes and hull-mounted systems.

  11. F11

    Platinized Titanium Anodes

    Titanium coated with a thin layer of platinum, used in seawater and other low-resistivity electrolytes.

  12. F12

    Platinized Niobium Anodes

    Platinum-coated niobium, which tolerates higher operating voltages than platinised titanium.

  13. F13

    Platinum Rod Anodes

    Platinum-clad rod anodes for compact, high-current seawater applications.

  14. F14

    Platinum Wire Anodes

    Platinum-clad wire anodes for linear and specialised installations.

  15. F15

    High Silicon Cast Iron (HSCI) Anodes

    Chromium-bearing high-silicon iron anodes for soil, fresh water and seawater groundbeds.

  16. F16

    High Silicon Iron Tubular Anodes

    Tubular HSCI anodes with centre connections for deep-well and surface groundbeds.

  17. F17

    High Silicon Iron Rod Anodes

    Solid HSCI rods for vertical and horizontal groundbeds.

  18. F18

    High Silicon Iron Plate Anodes

    HSCI plates for seawater and special installations.

  19. F19

    Graphite Anodes

    Graphite rods for soil groundbeds, typically installed in carbonaceous backfill.

  20. F20

    Canister Anodes

    Anodes pre-packed with coke backfill in a steel canister, for quicker groundbed installation.

  21. F21

    Deep Well Anodes

    Anode strings installed in deep vertical boreholes where surface space is limited or deeper soils have lower resistivity.

  22. F22

    Shallow Groundbed Anodes

    Anodes installed near the surface in vertical or horizontal groundbeds.

  23. F23

    Horizontal Groundbed Anodes

    Anodes laid horizontally in a trench, often where rock or a high water table prevents deep drilling.

  24. F24

    Vertical Groundbed Anodes

    Anodes installed vertically in a line of shallow boreholes.

  25. F25

    Conductive Polymer Anodes

    Linear anodes made from a conductive polymer around a copper conductor, for pipelines and tanks.

  26. F26

    Flexible Polymer Anodes

    Flexible conductive polymer anodes that follow the route of the structure being protected.

  27. F27

    Jackmo Wire Anodes

    Wire-type linear anodes for specialised installations, supplied to the project specification.

  28. F28

    Pyramid Anodes

    Pyramid-shaped anodes for specialised installations, supplied to the project specification.

  29. F29

    Lead-Silver Anodes

    Lead-silver alloy anodes for seawater ICCP systems.

  30. F30

    Probe Vessel Anodes

    Probe-type anodes inserted into vessels and tanks through a single connection.

Applications

Where these anodes are used.

Long pipelines

Transmission pipelines protected from groundbeds along the route.

Tank farms

Tank bottoms and internals using linear and grid anodes.

Reinforced concrete

Bridges, car parks and marine concrete using MMO mesh and ribbon.

Marine and seawater

Jetties, intakes and hulls using MMO and platinised anodes.

Enquiry

What to include in your enquiry.

  • Structure and total current requirement
  • Electrolyte (soil, fresh water, seawater, concrete)
  • Anode type, dimensions and quantity
  • Cable type, size and length
  • Groundbed type and backfill, if known
  • Design life and project specification
FAQ

Common questions.

What is the difference between sacrificial and impressed current anodes?

Sacrificial anodes generate their own current by corroding. Impressed current anodes are driven by an external power supply and are consumed very slowly, so fewer anodes can protect larger structures.

What is an MMO anode?

A titanium anode coated with mixed metal oxides. The coating conducts current with a very low consumption rate, making MMO anodes light, compact and long-lasting.

When is a deep well groundbed used?

Where surface space is limited, where there is interference with other structures, or where deeper soil layers have lower resistivity.

Do impressed current systems need maintenance?

Yes. Transformer-rectifiers and system potentials should be monitored regularly, as the system depends on a continuous power supply.